These guys aren't regular customers, but this kind of activity HAS to trickle down to others in Southern California.
http://www.mmsonline.com/blog/post/aerospace-company-goes-all-in-for-titanium-machining
Saturday, October 27, 2012
Sunday, June 24, 2012
I saw this yesterday and thought of those operators who walk on slippery gantrys every day:
http://www.mmsonline.com/articles/the-400-difference
Saturday, December 10, 2011
Fanuc Named Top Innovator
One of the things that encourages me to keep quoting Fanuc for our retrofits is the observation here that they have 600 engineers working on designs. In their heyday, MDSI had perhaps 10.
http://www.fanucfa.com/us-en/broker.jsp?uCon=4dc31aca-8c11-4318-e067-6b504c0394c7&uTem=5ef7107f-ee3a-6bea-1bcf-199
One of the things that encourages me to keep quoting Fanuc for our retrofits is the observation here that they have 600 engineers working on designs. In their heyday, MDSI had perhaps 10.
http://www.fanucfa.com/us-en/broker.jsp?uCon=4dc31aca-8c11-4318-e067-6b504c0394c7&uTem=5ef7107f-ee3a-6bea-1bcf-199
Monday, November 28, 2011
Hi - Scott found this link to all things Mitsubishi:
http://www.meau.com/eprise/main/sites/public/DOWNLOADS/-search_results?DocType=010&ManualType=0025
Warren
http://www.meau.com/eprise/main/sites/public/DOWNLOADS/-search_results?DocType=010&ManualType=0025
Warren
Saturday, November 12, 2011
Someday I'll Be Trained
I just returned from Precision Southwest in Tuscon. They had me working on their G&L four axis VTL that has been retrofitted with a OTT-C control. The sidehead axes have Heidenahain scales for feedback. The Z2 scale was defective and caused the axis to leap over what apparently was a bad spot in the glass. I was asked to disconnect the scale and just run the axis on the motor's feedback until the scale could be repaired. They just wanted to park the axis out of the way, so I didn't have to concern myself with zero return, reference counted scaling or exact encoder count.
I struggled for a day figuring out how this worked and it was NOT as easy as switching a couple of parameters like it is with a 16i control. The information was in the book for me to see, but was not obvious. Here's the main trick: The position feedback being used MUST always be connected to the same plug! So, one must UNPLUG the scale feedback and plug in the motor feedback to THAT connector where the scale was. This is an older 0-C, so things might be different now. This was the older incremental 2500 line encoder on a Red Cap motor. After swapping the motor feedback to the connector where the scale was, it was a simple matter of changing parameter 37.1 to a 0 to turn off the dual feedback to semi closed loop and all was well.
On another matter, check out this link:
http://www.businessweek.com/news/2011-11-12/no-sign-of-u-s-manufacturing-slump-as-machine-makers-outperform.html
Manufacturing seems to be picking up. That can't hurt our business.
I struggled for a day figuring out how this worked and it was NOT as easy as switching a couple of parameters like it is with a 16i control. The information was in the book for me to see, but was not obvious. Here's the main trick: The position feedback being used MUST always be connected to the same plug! So, one must UNPLUG the scale feedback and plug in the motor feedback to THAT connector where the scale was. This is an older 0-C, so things might be different now. This was the older incremental 2500 line encoder on a Red Cap motor. After swapping the motor feedback to the connector where the scale was, it was a simple matter of changing parameter 37.1 to a 0 to turn off the dual feedback to semi closed loop and all was well.
On another matter, check out this link:
http://www.businessweek.com/news/2011-11-12/no-sign-of-u-s-manufacturing-slump-as-machine-makers-outperform.html
Manufacturing seems to be picking up. That can't hurt our business.
Monday, September 5, 2011
September Happenings
I wanted to give you all a little update on some things around our company. As most of you know, I returned last week from a service call in Sarisota,FL. I was working on a Lucas Horizontal Boring Mill that used to be at STADCO in L.A. It has a GE 1050MC control and is now owned by Mustang Vacuum. They will use it to make their vacuum chambers. Their end product allows quick aluminum plating of plastic auto headlight lenses for customers around the world. Another use is plating auto wheels. They can apparently chrome plate an auto wheel in about 90 seconds! Dry! They've been selling to places like California where the toxic chemicals used on conventional plating is a problem.
Our retrofit schedule is very tight again. We are currently finishing up putting a used OTA on a LeBlond Regal at R.E. Atkinson. This project was completely installed and powered up by Andy and Basem while I was in Florida. The control came off of a nearly identical machine that was scrapped by R.A. Industries last year.
We are creating a Hydraulic Test Stand control for Circor in Corona. Jeff is finishing up the design after a slight setback last week. It turns out that the new line of low cost PLC's from AB is not quite ready for prime time. We'll revert to the Automation Direct/Koyo unit again.
Jeff is also rewriting PLC code for a gun drill for Alarin Hinge in Commerce. This new, custom machine had PLC code written by a "non motion control" guy and needs extensive rework. Jeff has much of the work done and needs to work on the HMI now.
Also, we just started a new lathe retrofit project at Circor in Sylmar. This will be a FS0iT-D control and a new spindle drive on a large Boehringer/VDF lathe.
Some of you remember Brian Crawford, who used to be a partner at Norotos. He is alive and well, living in Flagstaff. I've been there a couple of times to work on his machines and we keep in touch. Some of you may know that he is an experienced motorcycle "Trials" rider and competed well into his 70's. Now, it seems, he has a new project. You can read about it here: http://horndesigns-brian.tumblr.com/
Our retrofit schedule is very tight again. We are currently finishing up putting a used OTA on a LeBlond Regal at R.E. Atkinson. This project was completely installed and powered up by Andy and Basem while I was in Florida. The control came off of a nearly identical machine that was scrapped by R.A. Industries last year.
We are creating a Hydraulic Test Stand control for Circor in Corona. Jeff is finishing up the design after a slight setback last week. It turns out that the new line of low cost PLC's from AB is not quite ready for prime time. We'll revert to the Automation Direct/Koyo unit again.
Jeff is also rewriting PLC code for a gun drill for Alarin Hinge in Commerce. This new, custom machine had PLC code written by a "non motion control" guy and needs extensive rework. Jeff has much of the work done and needs to work on the HMI now.
Also, we just started a new lathe retrofit project at Circor in Sylmar. This will be a FS0iT-D control and a new spindle drive on a large Boehringer/VDF lathe.
Some of you remember Brian Crawford, who used to be a partner at Norotos. He is alive and well, living in Flagstaff. I've been there a couple of times to work on his machines and we keep in touch. Some of you may know that he is an experienced motorcycle "Trials" rider and competed well into his 70's. Now, it seems, he has a new project. You can read about it here: http://horndesigns-brian.tumblr.com/
Saturday, May 14, 2011
Pressure Sensitive Film
This might be old news to some of you but check out this Fuji product:
http://www.sensorprod.com/pr/md/index.php?mcode=prmd052011
The link that led me to this says it is new. Looks pretty interesting. I'm a little puzzled by the range: 7 to 43,000 PSI. It looks from the sample that the area from 20 to 3000 would be pretty hard to resolve.
http://www.sensorprod.com/pr/md/index.php?mcode=prmd052011
The link that led me to this says it is new. Looks pretty interesting. I'm a little puzzled by the range: 7 to 43,000 PSI. It looks from the sample that the area from 20 to 3000 would be pretty hard to resolve.
Subscribe to:
Comments (Atom)